<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-24 04-52-39
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 58 dBuV VOLTAGE
Pilot RDS Phase Difference
7.2 kHz 3.6 kHz -73 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 74 kHz 9998 25,3751
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
7,2 dBr 7,98 dBr 8,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 4:52, 24.03.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (58 dBuV) Max at: 74 kHz MIN: 15 kHz % above 76 kHz: 25,3751 Acquired: 2025/03/24 4:51:35 Total samples: 9998 Equivalent time: 0:08:19 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,8 dBr MIN: 7,2 dBr AVE: 7,98 dBr % above 10,2 dBr: 0,0 Last value: 7,3 dBr (2025/03/24 4:51:34) Station: 96.90 MHz, signal: 4/5 (58 dBuV) 04:45 04:46 04:47 04:48 04:49 04:50 04:51 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality